Polycom KIRK Wireless Server 6000 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Networking Polycom KIRK Wireless Server 6000. Polycom KIRK Wireless Server 6000 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 323
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
User Guide
Version 3.5
Verilink Corporation
127 Jetplex Circle
Madison, Alabama 35758
http://www.verilink.com
Copyright 2003 Polycom, Inc. All rights reserved.
NetEngine
TM
7000 Family, ACOS
TM
, Advanced Communications Engine
TM
, and Atlas Communication Engines, Inc., are trademarks of Polycom, Inc. All other brand or
product names are trademarks or registered trademarks of their respective companies or organizations. The information in this document is believed to be accurate.
No responsibility is assumed for errors or omissions. Verilink Corporation reserves the right to make changes without notice.
Part #: 3150-30626-001 Rev F
NetEngine
TM
6000 and 7000 Family
Przeglądanie stron 0
1 2 3 4 5 6 ... 322 323

Podsumowanie treści

Strona 1 - Version 3.5

User GuideVersion 3.5Verilink Corporation127 Jetplex CircleMadison, Alabama 35758http://www.verilink.comCopyright 2003 Polycom, Inc. All rights reserv

Strona 2

. - x - NetEngine IAD User Guideset dhcp server netbios ...247set dhcp server domain ...

Strona 3 - Table of Contents

NetEngine IAD User GuideWAN Configuration 81Configuring ATM PVCsYou may configure up to 8 ATM PVCs on the IAD. To configure create and manage PVCs, ty

Strona 4 - Chapter 4 WAN Configuration

NetEngine IAD User GuideWAN Configuration 824. The IAD displays the ATM Encapsulation Configuration menu.Figure 4–37. ATM Encapsulation Configuration

Strona 5

NetEngine IAD User GuideWAN Configuration 83Type the value for the peak cell rate.7. The IAD saves the configuration and displays the PVC Configuratio

Strona 6

NetEngine IAD User GuideWAN Configuration 84Setting up AAL5 or AAL0 Encapsulation1. Type 1 to select AAL5, or type 2 to select AAL0 encapsulation. 2.

Strona 7

NetEngine IAD User GuideWAN Configuration 85Figure 4–43. ATM Encapsulation Configuration Menu To select CBR, type 1. To select UBR, type 2.3. The IAD

Strona 8 - Chapter 11 NAT Configuration

NetEngine IAD User GuideWAN Configuration 86Figure 4–45. IPCP Configuration Menu Type the option corresponding to the IP address you want to use. 5.

Strona 9 - Chapter 12 IAD Reports

NetEngine IAD User GuideWAN Configuration 87Figure 4–47. ATM PCR Configuration Menu Type the PCR value or press Enter to set the PCR to the maximum r

Strona 10

NetEngine IAD User GuideWAN Configuration 88Type the PCR value or press Enter to set the PCR to the maximum rate for the current line speed.4. The IAD

Strona 11

NetEngine IAD User GuideWAN Configuration 89Deleting a PVCTo delete a PVC:1. Type 3 to select Delete PVC.2. The IAD displays the port list and a promp

Strona 12

NetEngine IAD User GuideWAN Configuration 90ConfiguringATM OptionsTo configure ATM options, type 4 to display the ATM Configuration menu:Figure 4–54.

Strona 13 - Preface xiv

. - xi - NetEngine IAD User GuideChapter 14 Troubleshooting and DiagnosticsUsing the Diagnostics Menu...

Strona 14 - Preface xv

NetEngine IAD User GuideWAN Configuration 91This value must match one of the WAN PVCs. For more information, see Configuring ATM PVCs on page 81. 2. T

Strona 15 - Regulatory

NetEngine IAD User GuideWAN Configuration 924. Press any key to display the ATM Configuration menu.Configuring EmptyCells1. On the ATM Configuration m

Strona 16 - IAD SOC/REN USOC FIC

NetEngine IAD User GuideWAN Configuration 93ConfiguringFrame Relay DLCIsTo configure Frame Relay DLCIs, type 3 on the WAN Configuration menu. The IAD

Strona 17 - Declaration of Conformity:

NetEngine IAD User GuideWAN Configuration 94Adding a DLCITo add a DLCI:1. On the Frame Relay DLCI Configuration menu, type 1 to select Add New DLCI.2.

Strona 18 - Preface xix

NetEngine IAD User GuideWAN Configuration 956. The IAD displays the throughput prompt:Enter the Circuit Throughput in bits/second (2048000): Type the

Strona 19 - Preface xx

NetEngine IAD User GuideWAN Configuration 9616. If you type 2, the IAD displays the fragment size prompt:Enter maximum fragment size in bytes (100-160

Strona 20 - 1. Introduction

NetEngine IAD User GuideWAN Configuration 97ConfiguringFrame Relay OptionsTo configure Frame Relay options, type 4 on the WAN Configuration menu. The

Strona 21 - 6000 IAD

NetEngine IAD User GuideWAN Configuration 98Figure 4–62. FRF.12 Configuration Menu Type the option and proceed to the corresponding section.Enabling

Strona 22 - LED Description

NetEngine IAD User GuideWAN Configuration 99Figure 4–63. FRF.12 Configuration Menu for CopperMountain Type the option and proceed to the correspondin

Strona 23 - Rear Panel Connectors

NetEngine IAD User GuideWAN Configuration 100Figure 4–64. Frame Relay Maintenance Protocol Menu 4. Type the number that corresponds to the protocol o

Strona 24 - 7000 IAD

NetEngine IAD User GuideThe Verilink NetEngine Family IAD User Guide contains the information you need to install, connect and configure each Verilink

Strona 25

NetEngine IAD User GuideWAN Configuration 101Enabling or Disabling Coppermountain CMCPTo enable or disable Coppermountain CMCP:1. On the Main menu, se

Strona 26 - Introduction 7

NetEngine IAD User GuideWAN Configuration 102Quick Con-figurationThe 6300 contains a number of predefined configurations for physical connections and

Strona 27 - Introduction 8

NetEngine IAD User GuideThis chapter describes how to configure the IAD as a router. You may configure the IAD as a router or a bridge, depending on y

Strona 28 - 2. Quick Start Guide

NetEngine IAD User GuideRouter Configuration 104Basic Router Setup TasksTo configure the IAD as a router, you should complete the following tasks:Conf

Strona 29 - Installing

NetEngine IAD User GuideRouter Configuration 105Router Configur-ation MenuRouter tasks are all displayed and accessed on the Router Configuration menu

Strona 30 - Emulator

NetEngine IAD User GuideRouter Configuration 106Configuringa Port IP AddressTo configure the IAD as a router, you must assign an IP address to both th

Strona 31 - Power Up the IAD

NetEngine IAD User GuideRouter Configuration 1078. Configuration is complete. The IAD displays the following prompt:Save new IP Information?->(Y)Ty

Strona 32 - Quick Start Guide 13

NetEngine IAD User GuideRouter Configuration 108Unconfig-uring a Port IP AddressTo unconfigure (delete) the IP address of an interface, follow these s

Strona 33 - Quick Start Guide 14

NetEngine IAD User GuideRouter Configuration 109Setting the Port Maximum Transmis-sion UnitThe MTU setting controls IP fragmentation of packets transm

Strona 34 - Resetting

NetEngine IAD User GuideRouter Configuration 110Enabling and Disabling RIPWhen you enable RIP, the IAD sends routing data to adjacent routers and dyna

Strona 35 - Connecting

NetEngine IAD User GuidePreface xivChapter 7, Voice Path Configuration on page 139, describes how to set up voice ports for use in various DSLAM and v

Strona 36 - Using the

NetEngine IAD User GuideRouter Configuration 111Setting the RIP VersionTo set the RIP version:1. Type V on the Router Configuration menu to select Con

Strona 37 - Quick Start Guide 18

NetEngine IAD User GuideRouter Configuration 112Managing Static and Default RoutesTo create, update and delete static and default routes, type S on th

Strona 38 - Entering Settings and Values

NetEngine IAD User GuideRouter Configuration 113Removing a Static RouteTo delete a static route from the Route Table:1. On the Router Modification men

Strona 39 - WAN Connections

NetEngine IAD User GuideRouter Configuration 114Config-uring DNS ClientDNS Client allows the IAD to use fully-qualified domain names; for example, www

Strona 40 - Telephone Connections

NetEngine IAD User GuideRouter Configuration 115Displaying the DNS Cache and StatisticsTo display information about the data in the DNS cache, type S.

Strona 41 - Confirming

NetEngine IAD User GuideRouter Configuration 116Config-uring DHCP ClientTo enable or disable DHCP Client on an interface, follow these steps:1. Type H

Strona 42 - 3. Administration

NetEngine IAD User GuideRouter Configuration 117Config-uring DHCP RelayDHCP Relay allows the IAD to forward DHCP requests from the LAN to a separate D

Strona 43 - Security

NetEngine IAD User GuideRouter Configuration 1184. Continue with other configuration tasks, or press Escape to return to the Router Modification menu.

Strona 44 - Changing a Password

NetEngine IAD User GuideRouter Configuration 119Configur-ing the Telnet Server PortWhen using NAT on the IAD, it is often desired to configure a host

Strona 45 - Administration 26

NetEngine IAD User GuideRouter Configuration 120Each of the tasks in this section originate at the IP Filtering Configuration menu. Type the option fo

Strona 46

NetEngine IAD User GuidePreface xvDo not spray liquids directly onto the system when cleaning. Always apply the liquid first to a static free cloth. D

Strona 47 - Administration 28

NetEngine IAD User GuideRouter Configuration 1213. The IAD enables or disables input filters, and displays the status of the output filters, with anot

Strona 48 - Setting Up

NetEngine IAD User GuideRouter Configuration 1222. Follow the IAD messages to enter values for the following parameters: 3. When you enter the last pa

Strona 49 - Disabling SNMP via IP and EOC

NetEngine IAD User GuideRouter Configuration 123Copying a FilterTo copy a filter to the filter buffer for viewing or editing, follow these steps:1. On

Strona 50 - Configuring the System Name

NetEngine IAD User GuideRouter Configuration 124Editing a Filter in the BufferTo edit a filter currently stored in the buffer, follow these steps:1. O

Strona 51 - Administration 32

NetEngine IAD User GuideRouter Configuration 125Deleting All Filters of the Chosen TypeTo delete all filters from the IP Filter table, toggle input or

Strona 52 - Upgrading

NetEngine IAD User GuideRouter Configuration 126Config-uring IP Header Compress-ion (IPHC)IPHC reduces the number of bytes transmitted across the WAN,

Strona 53 - Verifying the Upgrade

NetEngine IAD User GuideRouter Configuration 127Config-uring the LAN IP Broadcast DestinationTo set the LAN IP broadcast destination address (where al

Strona 54 - Connection

NetEngine IAD User GuideRouter Configuration 128

Strona 55 - Utilities

NetEngine IAD User GuideThis chapter describes how to configure the IAD as a bridge. A bridge is a device that connects and passes packets between two

Strona 56 - Setting up the USI Port

NetEngine IAD User GuideBridge Configuration 130Basic Bridge Setup TasksAlthough the IAD is pre-configured with bridging enabled, you should perform t

Strona 57 - Managing Configuration Files

NetEngine IAD User GuidePreface xviRegulatory NoticesFCC NoticeAll NetEngine products except the NE6100-4 have been tested and found to comply with th

Strona 58 - Displaying the Event Log

NetEngine IAD User GuideBridge Configuration 131Bridge Configur-ation MenuConfiguring the IAD as a bridge involves several tasks. These are all displa

Strona 59 - Administration 40

NetEngine IAD User GuideBridge Configuration 132Enabling and Disabling BridgingFor bridging to function correctly, you must enable bridging both globa

Strona 60 - File System

NetEngine IAD User GuideBridge Configuration 133Bridging is globally DISABLEDEnter E to Enable, D to Disable:Type E to enable bridging globally, or D

Strona 61 - Formatting the File System

NetEngine IAD User GuideBridge Configuration 134Setting the Bridge Aging TimerThe bridge aging timer establishes the amount of time that the IAD keeps

Strona 62

NetEngine IAD User GuideBridge Configuration 1351. G2237 xDSL2. 10/100BaseT Ethernet0. (Abort)Type the number of the port for which you want to enable

Strona 63 - Displaying Error Dumps

NetEngine IAD User GuideBridge Configuration 1363. If more than one interface is configured on the selected port, the IAD displays a list of interface

Strona 64 - Transfers

NetEngine IAD User GuideBridge Configuration 137Config-uring Spanning Tree Forward DelayTo set the Spanning Tree forward delay (a value between 4-30 s

Strona 65 - Using File Transfer Utilities

NetEngine IAD User GuideBridge Configuration 138Deleting a Bridge Forwarding Database EntryTo delete an Ethernet address from the bridge forwarding da

Strona 66 - Using the TFTP Server Menu

NetEngine IAD User GuideAfter you have defined the voice PVCs or DLCIs on the IAD, you should configure the voice path for voice operation to function

Strona 67 - Derived

NetEngine IAD User GuideVoice Path Configuration 140Basic Voice Path Setup TasksTo configure voice path settings, you should complete the following ta

Strona 68 - Verifying

NetEngine IAD User GuidePreface xviiBefore connecting your IAD, you must inform the telephone company of the following information. An FCC compliant t

Strona 69 - Administration 50

NetEngine IAD User GuideVoice Path Configuration 141Setting the Voice GatewayTo select a voice gateway:1. Type V on the Voice Configuration menu to se

Strona 70 - 4. WAN Configuration

NetEngine IAD User GuideVoice Path Configuration 1424. Reset the IAD (page 15) when you finish voice path configuration.When you choose a specific voi

Strona 71 - Basic WAN

NetEngine IAD User GuideVoice Path Configuration 143Displaying Jitter DelayTo display the current jitter delay value, type D on the Voice Configuratio

Strona 72 - WAN Configuration 53

NetEngine IAD User GuideVoice Path Configuration 144Configuring Start Mode on an Individual Port1. Type 4 on the Start Mode Selection menu to select C

Strona 73

NetEngine IAD User GuideVoice Path Configuration 145Setting Compander ModeTo set Compander Mode, type U to display the Compander Mode Selection menu:F

Strona 74

NetEngine IAD User GuideVoice Path Configuration 146Setting Idle Voltage ModeTo set idle high voltage for loop start lines (POTS only), type L to disp

Strona 75 - WAN Configuration 56

NetEngine IAD User GuideVoice Path Configuration 147Setting Debug ModeOption M, Set Debug Mode, is reserved for Verilink network engineers.Configur-in

Strona 76 - Selecting ATM or Frame Relay

NetEngine IAD User GuideVoice Path Configuration 148Setting Loop GainIf the IAD feeds telephone circuits into a legacy PBX or other equipment that def

Strona 77 - TDM Voice

NetEngine IAD User GuideVoice Path Configuration 149Displaying Loop Gain SettingsTo display information about Loop Gain settings, type 2. The IAD disp

Strona 78 - WAN Configuration 59

NetEngine IAD User GuideVoice Path Configuration 150Setting Country ModeThe country mode selection menu allows you to select a national parameter list

Strona 79 - Selecting

NetEngine IAD User GuidePreface xviiiappropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipmen

Strona 80 - G.SHDSL

NetEngine IAD User GuideVoice Path Configuration 151Managing MGCP Embedded ClientThis section applies to MGCP—Voice Over IP—gateway management.To conf

Strona 81 - Selecting the Line Rate

NetEngine IAD User GuideVoice Path Configuration 152Available Interfaces:1. G2237 xDSL2. 10/100BaseT Ethernet0. (Abort)Selection:Type the option numbe

Strona 82 - Interface—

NetEngine IAD User GuideVoice Path Configuration 153Port AdministrationType A to display the Port Administration menu:Figure 7–13. Port Administratio

Strona 83

NetEngine IAD User GuideVoice Path Configuration 154Restarting an EndpointType 4 to reset the connection between the Voice Port phone and the MGCP voi

Strona 84

NetEngine IAD User GuideVoice Path Configuration 155Managing Copper-Com Call ControlWhen your IAD is configured for connection to a Coppercom Voice Ga

Strona 85 - WAN Configuration 66

NetEngine IAD User GuideVoice Path Configuration 156Figure 7–16. CopperCom Configuration Menu Type the option for the command to execute and proceed

Strona 86 - Setting SDSL Interface Mode

NetEngine IAD User GuideVoice Path Configuration 157Type 1 to select a 36 octet packet, using a single packet per frame, or type 2 to select a 44 octe

Strona 87 - Using the Debug Menu

NetEngine IAD User GuideVoice Path Configuration 158JetStream Call Control SettingsWhen you have specified the JetStream Voice Gateway, type E to disp

Strona 88

NetEngine IAD User GuideVoice Path Configuration 159Configuring the Ring TestType C to configure the ring test.1. The IAD displays the port prompt:Por

Strona 89 - T1 or E1

NetEngine IAD User GuideVoice Path Configuration 160Figure 7–20. Ring Test Menu for JetStream Voice Gateway Type 0 to replace the dial tone with sile

Strona 90 - Switching from E1 to T1

NetEngine IAD User GuidePreface xixKonformitetserklæring:Hermed erklærer Polyspan Ltd., at indestående NetEngine er i overensstemmelse med de grundlæg

Strona 91

NetEngine IAD User GuideVoice Path Configuration 161Configur-ing AAL2/LES CASATM Adaptation Layer 2/Loop Emulation Services (AAL2/LES) is a broadband

Strona 92 - Configuring Loopback

NetEngine IAD User GuideVoice Path Configuration 162settings is a message indicating the IAD will be configured for the selected gateway after reset.3

Strona 93 - WAN Configuration 74

NetEngine IAD User GuideVoice Path Configuration 1634. Reset the IAD (page 15) when you finish voice path configuration.Changing the Maximum CPS-SDU S

Strona 94 - WAN Configuration 75

NetEngine IAD User GuideVoice Path Configuration 164Manual ATM pace control (disabled) [E/D]:3. Type E to enable pace control, or D to disable pace co

Strona 95

NetEngine IAD User GuideVoice Path Configuration 165Configur-ing AAL2/LES CCS-ELCPATM Adaptation Layer 2/Loop Emulation Services (AAL2/LES) is a broad

Strona 96 - Configuring S-Bits

NetEngine IAD User GuideVoice Path Configuration 166Debugging for AAL2/LES CCS-ELCPType D to display the Debugging menu:Figure 7–29. AAL2/LES CCS-ELC

Strona 97 - WAN Configuration 78

NetEngine IAD User GuideVoice Path Configuration 167Displaying AAL2 Channel StatisticsType D to display the AAL2 channel statistics:<<< Audio

Strona 98 - WAN Configuration 79

NetEngine IAD User GuideVoice Path Configuration 168

Strona 99 - WAN Configuration 80

NetEngine IAD User GuideCreating a Firewall via IP FilteringFirewall configuration (also known as IP filtering) allows you to specify a combination of

Strona 100 - ATM PVCs

NetEngine IAD User GuideFirewall Configuration 170

Strona 101 - WAN Configuration 82

NetEngine IAD User GuidePreface xx

Strona 102 - Modifying a PVC

NetEngine IAD User GuideThis chapter describes the tasks required to configure the Dynamic Host Configuration Protocol (DHCP) server on the LAN connec

Strona 103 - Encapsulation)

NetEngine IAD User GuideDHCP Server Configuration 172Basic DHCP Server Setup TasksWhen DHCP is enabled, it dynamically assigns an IP address to each d

Strona 104 - WAN Configuration 85

NetEngine IAD User GuideDHCP Server Configuration 173Using DHCP Debugging MessagesThe commands in option B, Enable/Disable DHCP Debug Messages, are re

Strona 105 - WAN Configuration 86

NetEngine IAD User GuideDHCP Server Configuration 174Configur-ing DHCP Server ParametersTo configure DHCP Server parameters, type I on the DHCP Server

Strona 106 - Setting up AAL1/CES

NetEngine IAD User GuideDHCP Server Configuration 175Configuringthe DHCP Address Range PoolYou must configure the DHCP address range pool to set the r

Strona 107 - Setting up AAL2/LES

NetEngine IAD User GuideDHCP Server Configuration 176Enter Y to enter a value for Subnet MaskEnter N to use a default valueCurrent Subnet Mask = 0.0.0

Strona 108 - Showing Current PVCs

NetEngine IAD User GuideDHCP Server Configuration 177Displaying DHCP Server Details13. Type F to display the current configuration of the DHCP Server:

Strona 109 - Configuring

NetEngine IAD User GuideDHCP Server Configuration 178Displaying DHCP Server Statistics Type S to display DHCP Server statistics. The IAD displays the

Strona 110 - Sending OAM Loopback

NetEngine IAD User GuideDHCP Server Configuration 179Displaying DHCP Entry DetailsType D to display DHCP entry details. The IAD displays the following

Strona 111 - Configuring EmptyCells

NetEngine IAD User GuideDHCP Server Configuration 180

Strona 113 - Adding a DLCI

NetEngine IAD User GuideThis chapter introduces Verilink’s NetEngine 6000 and 7000 family Integrated Access Devices (IAD) and describes their hardware

Strona 114 - WAN Configuration 95

NetEngine IAD User GuideMulticast (point-to-multipoint) is a communication feature that allows a source host to send a message to a group of destinati

Strona 115 - Displaying Current DLCIs

NetEngine IAD User GuideMulticast Configuration 182Configur-ing MulticastType M to display the Multicast Configuration menu: Figure 10–1. Multicast C

Strona 116

NetEngine IAD User GuideMulticast Configuration 183Configur-ing PIM—Dense Mode by PortType P to configure Protocol-Independent Multicast (PIM) version

Strona 117 - WAN Configuration 98

NetEngine IAD User GuideMulticast Configuration 184Adding a Multicast Routing SourceType A to add a Multicast Routing Source. The IAD creates a multic

Strona 118 - WAN Configuration 99

NetEngine IAD User GuideMulticast Configuration 185Removing a Multicast Routing SourceType R to remove a Multicast Routing Source:1. The IAD displays

Strona 119 - WAN Configuration 100

NetEngine IAD User GuideMulticast Configuration 186Displaying the IGMP GroupIGMP is a communication protocol that operates between a router (The IAD)

Strona 120 - Toggling CMCP Debugging

NetEngine IAD User GuideMulticast Configuration 187Since Multicast packets are forwarded according to the preceding information, this table is the key

Strona 121 - Quick Con

NetEngine IAD User GuideMulticast Configuration 188

Strona 122 - 5. Router Configuration

NetEngine IAD User GuideThis chapter describes the steps required to configure Network Address Translation (NAT).NAT multiplexes traffic from the inte

Strona 123 - Router Configuration 104

NetEngine IAD User GuideNAT Configuration 190The NAT ConfigurationMenuEnabling and managing NAT involves several tasks. These are all displayed and ac

Strona 124 - Configur

NetEngine IAD User GuideIntroduction 2Data InterfacesThe data connection through the IAD supports IEEE 802.10-compliant bridging and routing.When the

Strona 125

NetEngine IAD User GuideNAT Configuration 191A significant advantage of NAT is that you can configure it without changing hosts or routers, other than

Strona 126 - Router Configuration 107

NetEngine IAD User GuideNAT Configuration 192ConfiguringNAT Local ServerTo configure the NAT local server entry, follow these steps:1. Type N on the N

Strona 127 - IP Address

NetEngine IAD User GuideNAT Configuration 19310. The IAD displays this port report:Updating NAT Local Server entry 1, Translated IP address 91.1.1.200

Strona 128 - Transmis

NetEngine IAD User GuideNAT Configuration 194Configuringthe NAT Port RangeThe size of the NAT port range defines the number of simultaneous connection

Strona 129 - Disabling

NetEngine IAD User GuideNAT Configuration 195Configuringthe NAT Alias EntryEach NAT alias entry allows a device on the LAN (inside of NAT) to be acces

Strona 130 - Setting the RIP Version

NetEngine IAD User GuideNAT Configuration 196NAT StatisticsWhen NAT is enabled, you can review statistics gathered as NAT operates. To display NAT sta

Strona 131 - Default

NetEngine IAD User GuideNAT Configuration 197NAT Connection TableWhen NAT is enabled, you can display the current open connections. To display the con

Strona 132

NetEngine IAD User GuideNAT Configuration 198If the connection is not open, the IAD advises you. Press any key to return to the NAT Configuration menu

Strona 133 - Router Configuration 114

NetEngine IAD User GuideNAT Configuration 199NAT Local Server TableWhen NAT is enabled, you can display the entries in the local server table. To disp

Strona 134 - Router Configuration 115

NetEngine IAD User GuideNAT Configuration 200Deleting a NAT Local Server EntryTo delete a local server entry:1. Type Y on the NAT Configuration menu.

Strona 135 - Router Configuration 116

NetEngine IAD User GuideIntroduction 3NetEngine 6500 IADs—provides voice services and high-speed Internet or corporate connectivity over G.SHDSL, and

Strona 136 - Router Configuration 117

NetEngine IAD User GuideThis chapter describes the report subsystem in the IAD. The report subsystem allows you to display information about the curre

Strona 137 - Router Configuration 118

NetEngine IAD User GuideIAD Reports 202The Report MenuTo display the Reports menu, type 1 on the Main menu.Figure 12–1. Reports MenuMost options on t

Strona 138 - Router Configuration 119

NetEngine IAD User GuideIAD Reports 203Current Configur-ation ReportTo display the Current Configuration report, enter C on the Reports menu. The Curr

Strona 139 - Router Configuration 120

NetEngine IAD User GuideIAD Reports 204WAN DataLink Protocol Totally Transparent | Raw HDLC | Cisco compatible HDLC | IP-Plus compatible HDLC | PPP (o

Strona 140 - T1/E1 Output Filters: Enabled

NetEngine IAD User GuideIAD Reports 205Sa8 Bit set | clearedRcv Clk Source Internal | ExternalPPP Auth Type (WAN port) None | PAP Client | PAP Server

Strona 141 - Copying Filters for Editing

NetEngine IAD User GuideIAD Reports 206Network Statistics ReportsThe Network Statistics menu contains commands to display statistical information abou

Strona 142 - Copying a Filter

NetEngine IAD User GuideIAD Reports 207discarded for other reasons: - unrecognized codes - bad checksum - packets smaller than header - redirects from

Strona 143

NetEngine IAD User GuideIAD Reports 208IGMP Statistics ReportTo display the IGMP Statistics report, type G on the Network Statistics menu. The IGMP St

Strona 144 - Router Configuration 125

NetEngine IAD User GuideIAD Reports 209IP Statistics ReportTo display the IP Statistics report, type I on the Network Statistics menu. The IP Statisti

Strona 145 - Compress

NetEngine IAD User GuideIAD Reports 210discarded for lack of resourcesDiscarded received packets due to lack of resources: kernel memory, packet buffe

Strona 146 - Router Configuration 127

NetEngine IAD User GuideIntroduction 4Rear Panel ConnectorsOn the rear panel (Figure 1–3), the IAD contains several connectors. The type and position

Strona 147 - Router Configuration 128

NetEngine IAD User GuideIAD Reports 211PIM Statistics ReportTo display the PIM Statistics report, type P on the Network Statistics menu. The PIM Stati

Strona 148 - 6. Bridge Configuration

NetEngine IAD User GuideIAD Reports 212TCP Statistics ReportTo display the TCP Statistics report, type T on the Network Statistics menu. The TCP Stati

Strona 149 - Bridge Configuration 130

NetEngine IAD User GuideIAD Reports 213UDP Statistics ReportTo display the UDP Statistics report, type U on the Network Statistics menu. The UDP Stati

Strona 150

NetEngine IAD User GuideIAD Reports 214Clearing Network StatisticsTo clear network statistics, type Z on the Network Statistics menu. The IAD displays

Strona 151 - Bridging

NetEngine IAD User GuideIAD Reports 215Interface Statistics ReportsType I on the Reports menu to display interface statistics reports. The Interface S

Strona 152 - Bridge Configuration 133

NetEngine IAD User GuideIAD Reports 216ARP Statistics Report To display the ARP Statistics report, type A on the Interface Statistics menu. The ARP St

Strona 153 - Bridge Configuration 134

NetEngine IAD User GuideIAD Reports 217Interface Statistics Report To display the Interface Statistics report, type I on the Interface Statistics menu

Strona 154 - Bridge Configuration 135

NetEngine IAD User GuideIAD Reports 218Bridge Statistics ReportTo display the Bridge Statistics report, type B on the Interface Statistics menu. This

Strona 155 - Bridge Configuration 136

NetEngine IAD User GuideIAD Reports 219Table 12–11.DLCI StatisticsParameter DescriptionCommitted Burst No. of committed info rate (bytes per measureme

Strona 156 - Bridge Configuration 137

NetEngine IAD User GuideIAD Reports 220ATM PVC Statistics ReportTo display the PVC Statistics Reports, type A on the Interface Statistics menu. This o

Strona 157 - Database

NetEngine IAD User GuideIntroduction 5NetEngine 7000 IAD FamilyThe Verilink NetEngine 7000 IAD family provides a highly interoperable, cost-effectiv

Strona 158 - Configuration

NetEngine IAD User GuideIAD Reports 221AAL2 Statistics ReportThis PVC Report displays when an AAL2/LES PVC is configured.Table 12–13.Common CPCS-2 Sta

Strona 159 - Voice Path Configuration 140

NetEngine IAD User GuideIAD Reports 222Cumulative CPCS-2 Statistics Report Common AAL Statistics ReportThis report displays when ATM protocol is confi

Strona 160

NetEngine IAD User GuideIAD Reports 223Max PDU Max. PDU size limitation for this AAL connection.Rx Frames No. of frames received.Rx Cells No. of AAL c

Strona 161 - Jitter Delay

NetEngine IAD User GuideIAD Reports 224IP Header Compression Statistics ReportThis report is available when ATM PVC Encapsulation Type RFC 1483 is sel

Strona 162 - Start Mode

NetEngine IAD User GuideIAD Reports 225PPP Statistics ReportThis report is available when ATM PVC Encapsulation Type RFC 2364 is selected. Clearing In

Strona 163 - Control

NetEngine IAD User GuideIAD Reports 226Media Statistics ReportsType M on the Reports menu to display Media statistics reports. Media statistics report

Strona 164 - Voice Path Configuration 145

NetEngine IAD User GuideIAD Reports 227Frame Relay Statistics Report Type F to display the Frame Relay Statistics report. This report displays basic a

Strona 165 - Voltage

NetEngine IAD User GuideIAD Reports 228Serial (USI) Statistics ReportType S to display the Serial Statistics report. This report displays basic serial

Strona 166 - Voice Path Configuration 147

NetEngine IAD User GuideIAD Reports 229ATM Statistics ReportThis report displays basic ATM transport statistics at the cell level for all ports and PV

Strona 167 - Loop Gain

NetEngine IAD User GuideIAD Reports 230OAM Tx No. of cells transmitted with CLPI (Cell Loss Priority Indication) bit is on.CLPI Tx No. of OAM (Operati

Strona 168 - Displaying Loop Gain Settings

NetEngine IAD User GuideIntroduction 6Figure 1–4. 7000 Family IAD Front Panel Rear Panel ConnectorsOn the rear panel, the IAD contains several connec

Strona 169 - Country

NetEngine IAD User GuideIAD Reports 231G2237 xDSL Statistics Report Table 12–21.G2237 xDSL Statistics ReportParameter DescriptionOperational State Cur

Strona 170 - Embedded

NetEngine IAD User GuideIAD Reports 232H.DSL2Remote HDSL2 Version Current version of the Remote HDSL2.Remote Country Code Current Remote Country Code.

Strona 171 - Removing a Connection

NetEngine IAD User GuideIAD Reports 233Ethernet Statistics ReportTable 12–22.Ethernet Statistics ReportParameter DescriptionReceived Packet Informatio

Strona 172 - Port Administration

NetEngine IAD User GuideIAD Reports 234carrier sense lost No. of times that the carrier sense condition was lost or never asserted when attempting to

Strona 173 - Voice Path Configuration 154

NetEngine IAD User GuideIAD Reports 235G7070 ADSL Statistics Report Table 12–23.G7070 ADSL Statistics ReportParameter DescriptionOperational Seconds T

Strona 174 - Com Call

NetEngine IAD User GuideIAD Reports 236POTS Statistics ReportTable 12–24.POTS Statistics ReportParameter DescriptionLine X Active/Inactive Current sta

Strona 175 - Voice Path Configuration 156

NetEngine IAD User GuideIAD Reports 237BRI Statistics Report Clearing Media StatisticsTo clear network statistics, type Z on the Network Statistics me

Strona 176 - CopperCom Debug Control

NetEngine IAD User GuideIAD Reports 238Continue resetting network statistics, or press Escape to return to the Network Statistics menu.Route Table Rep

Strona 177 - Settings

NetEngine IAD User GuideIAD Reports 239You must enable bridging for this table to display. For more information on enabling bridging, see Bridge Confi

Strona 178 - Displaying the IAD State

NetEngine IAD User GuideIAD Reports 240Otherwise, the following information is displayed for each entry:Press any key to return to the Reports menu.Sy

Strona 179 - Resetting Statistics

NetEngine IAD User GuideIntroduction 7AC PowerConnects the IAD to an AC outlet of 108-130 volts via an AC power cord.10/100Base-T Ethernet PortConnect

Strona 180

NetEngine IAD User GuideIAD Reports 241Highest Memory Used 901KB (922959 Bytes)Kernel Free Memory 241KB (247016 Bytes)Free Blocks 1 BlocksLargest Free

Strona 181 - Manual Configuration

NetEngine IAD User GuideIAD Reports 242

Strona 182 - Voice Path Configuration 163

NetEngine IAD User GuideIntro-ductionThe command line interface is often more convenient to use than the menu interface. Many of the tasks you normall

Strona 183 - Debugging AAL2/LES Gateways

NetEngine IAD User GuideCommand Line Interface 244on | offKeywords to enable (on) or disable (off) STP.slotNumeric value identifying the connection (0

Strona 184 - LES CCS

NetEngine IAD User GuideCommand Line Interface 245Command Line Interface ReferenceEach command in the command line interface is described below, in al

Strona 185 - Viewing AAL2/LES Statistics

NetEngine IAD User GuideCommand Line Interface 246reset systemDescription. Performs a soft system reset. reset systemDiscussion. Any time you use the

Strona 186 - Voice Path Configuration 167

NetEngine IAD User GuideCommand Line Interface 247set bridge stp globalDescription. Enables or disables Spanning Tree Protocol globally.set bridge stp

Strona 187 - Voice Path Configuration 168

NetEngine IAD User GuideCommand Line Interface 248set dhcp server rangeDescription. Sets the DHCP server low and high IP address range.set dhcp server

Strona 188 - 8. Firewall Configuration

NetEngine IAD User GuideCommand Line Interface 249set lan bridgeDescription. Enables or disables bridging on a LAN port.set lan bridge <on | off>

Strona 189 - Firewall Configuration 170

NetEngine IAD User GuideCommand Line Interface 250set lan rip Description. Enables or disables RIP on a WAN IP port If you do not enter any optional p

Strona 190 - 9. DHCP Server

NetEngine IAD User GuideIntroduction 8

Strona 191 - DHCP Server Configuration 172

NetEngine IAD User GuideCommand Line Interface 251set mgcp listening portDescription. Specifies the UDP port the Notified Entity (call agent) is liste

Strona 192 - DHCP Server Configuration 173

NetEngine IAD User GuideCommand Line Interface 252set mgcp voice connectionDescription. Specifies the slot, interface, port, and connection for the vo

Strona 193 - Parameters

NetEngine IAD User GuideCommand Line Interface 253set sdsl speedDescription. Sets the SDSL speed. This command sets the speed to manual framed (Nokia)

Strona 194

NetEngine IAD User GuideCommand Line Interface 254set wan atm vcDescription. Sets an ATM VC on a given WAN port—RFC 1483 and RFC 2364 VC Muxing PVCs,

Strona 195 - DHCP Server Configuration 176

NetEngine IAD User GuideCommand Line Interface 255set wan datalinkDescription. Sets the datalink protocol to Frame Relay or ATM. If you don’t enter op

Strona 196

NetEngine IAD User GuideCommand Line Interface 256set wan ip addressDescription. Sets the WAN IP address. If you do not enter any optional parameters,

Strona 197 - Field Description

NetEngine IAD User GuideCommand Line Interface 257set wan rip Description. Enables and disables RIP on a WAN IP port. If you do not enter any optional

Strona 198 - Value Description

NetEngine IAD User GuideCommand Line Interface 258

Strona 199 - DHCP Server Configuration 180

NetEngine IAD User GuideThis chapter describes procedures for troubleshooting and diagnosing problems that may be associated with the IAD.Diagnostics

Strona 200 - 10. Multicast

NetEngine IAD User GuideTroubleshooting and Diagnostics 260Using the DiagnosticsMenuDiagnostic tasks are all displayed and accessed on the Diagnostics

Strona 201 - Multicast Configuration 182

NetEngine IAD User GuideThis chapter describes the steps to install, connect, and set the IP address of the NetEngine IAD. It introduces the menu inte

Strona 202 - Multicast Configuration 183

NetEngine IAD User GuideTroubleshooting and Diagnostics 261To perform a specific test, type the option and proceed to the corresponding section.Perfor

Strona 203 - Routing

NetEngine IAD User GuideTroubleshooting and Diagnostics 262Lines 3 and 4 are connected togetherLines 5 and 6 are connected togetherLines 7 and 8 are c

Strona 204 - Multicast Configuration 185

NetEngine IAD User GuideTroubleshooting and Diagnostics 263—or—Type N to test a specific line. The IAD prompts you for the port number.3. The IAD prom

Strona 205 - Multicast Configuration 186

NetEngine IAD User GuideTroubleshooting and Diagnostics 264Performing an On/Off Hook TestThe On/Off Hook test reports the hook state of each voice por

Strona 206 - Neighbor

NetEngine IAD User GuideTroubleshooting and Diagnostics 265SDSL DiagnosticsTo perform SDSL diagnostics, type S on the Diagnostics menu.The IAD display

Strona 207 - Multicast Configuration 188

NetEngine IAD User GuideTroubleshooting and Diagnostics 266ISDN-BRI DiagnosticsType B to perform BRI Diagnostics. The IAD displays the BRI Diagnostics

Strona 208 - 11. NAT Configuration

NetEngine IAD User GuideTroubleshooting and Diagnostics 267Trouble-shooting the IADThis section provides information for troubleshooting symptoms asso

Strona 209

NetEngine IAD User GuideTroubleshooting and Diagnostics 268Cannot receive or send dataIncorrect PVC/DLCI set for data channelVerify these settings:VPI

Strona 210 - Translation

NetEngine IAD User GuideTroubleshooting and Diagnostics 269The table following lists the IAD provisioning parameters on the voice gateway that identif

Strona 211

NetEngine IAD User GuideTroubleshooting and Diagnostics 270

Strona 212

NetEngine IAD User GuideQuick Start Guide 10Unpacking the IADEach IAD is packed and shipped in a durable container. If you haven’t already done so, op

Strona 213

NetEngine IAD User GuideThis chapter describes how to verify that the NetEngine IAD operates properly after installation. It also covers maintenance a

Strona 214

NetEngine IAD User GuideVerification 272Power-up TestThe NetEngine IAD displays an indication of normal operation when you first power it up. When you

Strona 215

NetEngine IAD User GuideVerification 27311. Using a straight-through cable, connect the Ethernet LAN port on the IAD to your local LAN patch panel or

Strona 216 - Report Entry Description

NetEngine IAD User GuideVerification 274

Strona 217

NetEngine IAD User GuideMenu Map This appendix provide a map of the menu interface for the NetEngine family of IADs.A. Menu MapLog OnMain MenuESC(Log

Strona 218 - Table 11–6.NAT Alias Table

NetEngine IAD User GuideMenu Map 276P. VoicePathConfigure*J. Set Jitter DelayD. Display Jitter DelayS. Set Start Mode(Loop Start/Ground Start)T. Set

Strona 219 - NAT Configuration 200

NetEngine IAD User GuideCountry Codes TablesThis appendix specifies the settings for each country code setting supported by the IAD. When you select a

Strona 220 - 12. IAD Reports

NetEngine IAD User GuideCountry Codes 278Table B–3. Country Code Settings—Belgium2, Denmark, and ItalyParameters Belgium2 Denmark ItalyMin. Flash Hook

Strona 221 - The Report

NetEngine IAD User GuideThis appendix list the specifications for the 6000 NetEngine IAD family, including the 6100, 6200, 6300 and 6500, and the 7000

Strona 222 - Current

NetEngine IAD User GuideNetEngine IAD Specifications 280 REN 6100-4,6204/8,6204/8c,6300-4/86108,6504/82.5 REN per port5 REN per portLoop Current 6100-

Strona 223 - Parameter Description

. - iii - NetEngine IAD User Guide Table of ContentsPrefaceAudience...xi

Strona 224

NetEngine IAD User GuideQuick Start Guide 11vertically, ensure at least 3 inches of distance between other IADs or other equipment. Wiring Requirement

Strona 225 - Network

NetEngine IAD User GuideNetEngine IAD Specifications 281 Table C–3. 6000 Family Digital Voice Features Feature DescriptionCompression G.711 (64 kbps

Strona 226

NetEngine IAD User GuideNetEngine IAD Specifications 282Table C–5. 6000 Family WAN Interface Features Feature DescriptionADSL G.lite, G.dmt—6100-4WAN

Strona 227 - IGMP Statistics Report

NetEngine IAD User GuideNetEngine IAD Specifications 283DSLAMs Cisco, Coppermountain, Innovia, Lucent, NokiaVoice Gateways CopperCom, JetStream; AAL2/

Strona 228 - IP Statistics Report

NetEngine IAD User GuideNetEngine IAD Specifications 284 Table C–6. 6000 Family Transport Protocol Features Feature DescriptionATMAdaption Layers AAL

Strona 229

NetEngine IAD User GuideNetEngine IAD Specifications 285 Table C–8. 6000 Family Security FeaturesFeature DescriptionFirewall IP Filtering (in and out

Strona 230 - - packets smaller than

NetEngine IAD User GuideNetEngine IAD Specifications 2867000 Family The 7000 family is comprised of the NetEngine 7200 and NetEngine 7300. The IADs sh

Strona 231 - TCP Statistics Report

NetEngine IAD User GuideNetEngine IAD Specifications 287 Table C–12. 7000 Family Data Features Feature DescriptionLAN Interface 10/100 BaseT Ethernet

Strona 232 - UDP Statistics Report

NetEngine IAD User GuideNetEngine IAD Specifications 288Cell Delay Variation BufferConfigurable 0-30 msOAM Cell Handling F4|F5 segment and end-to-end

Strona 233 - Clearing Network Statistics

NetEngine IAD User GuideConnector PinoutsThis appendix specifies pinouts for each connector on the IAD. D. Connector PinoutsTable D–1. RS-232 DB-9 Co

Strona 234 - Interface

NetEngine IAD User GuideConnector Pinouts 290Table D–4. 10BaseT Connector Pin AssignmentsPin Signal Pin Signal1Tx+ 5NC2Tx- 6Rx-3Rx+7NC4NC 8NCTable D–5

Strona 235 - ARP Statistics Report

NetEngine IAD User GuideQuick Start Guide 12Power Up the IAD1. With the console cable connected, on 6000 family IADs plug the AC power adapter into th

Strona 236 - Interface Statistics Report

NetEngine IAD User GuideConnector Pinouts 291Table D–8. T1/E1 Connector Pin AssignmentsPin Signal Pin Signal1Rx Ring5Tx Ring2Rx Tip6NC3NC 7NC4Tx Tip8N

Strona 237 - DLCI Statistics Report

NetEngine IAD User GuideConnector Pinouts 292

Strona 238 - Table 12–11.DLCI Statistics

NetEngine IAD User GuideGlossary 10/100BaseT. 10-Mbps baseband Ethernet specification that uses two pairs of twisted-pair cabling: one pair for transm

Strona 239 - AAL1 CPCS Statistics Report

NetEngine IAD User GuideGlossary 294IGMP. Internet Group Management Protocol. Transport layer multicasting protocol used by IP hosts to register their

Strona 240 - AAL2 Statistics Report

NetEngine IAD User GuideGlossary 295OSI Reference Model. Network architectural model developed by ISO and ITU-T. The model consists of the following s

Strona 241 - Common AAL Statistics Report

NetEngine IAD User GuideGlossary 296Router. Network layer device that uses one or more metrics to determine the optimal path to forward network traffi

Strona 242

- 2 - NetEngine IAD User GuideNumerics10/100Base-T Ethernet 4, 76000 familyfeatures of 2front panel 3generallyIADs described 2rear panel 4telephone in

Strona 243

- 3 - NetEngine IAD User GuideCCE mark xviiiChannel Configuration menu 74, 78Cisco 282supported DSLAM 282CODEC, testing 262command line interface refe

Strona 244 - Clearing Interface Statistics

- 4 - NetEngine IAD User GuideEIA-530 interface for USI 21EmptyCells, configuring 92Encapsulationsetting proprietary voice 84Encapsulation, setting in

Strona 245

- 5 - NetEngine IAD User GuideIP filtering 169filter parameters 122filter, deleting 124filter, details 123filters, deleting by type 125filters, displa

Strona 246 - DLCIs)

NetEngine IAD User GuideQuick Start Guide 137. Type the default password (supervisor, or your password if different) and press Enter.8. If log in is n

Strona 247

- 6 - NetEngine IAD User GuideT1 Configuration 70, 72T1 Frame Mode 72TFTP Server 47Tx Clock Source (E1) 79Utilities 33Utilities (7000) 36Voice Configu

Strona 248 - ATM Statistics Report

- 7 - NetEngine IAD User GuideQQuick Configuration menu 102quick configuration, using in 6300 102quit CLI command 245RRADIUS configurationdisplaying 2

Strona 249

- 8 - NetEngine IAD User GuideSystem Contact, configuring 30System Location, configuring 31System Name, configuring 31Trap Host IP address, configurin

Strona 250 - G2237 xDSL Statistics Report

- 9 - NetEngine IAD User GuideWAN setupADSL with ATM 54E1 with ATM 54E1 with Frame Relay 54G.SHDSL with ATM 55SDSL with ATM 55SDSL with ATM (6300, 730

Strona 251

NetEngine IAD User GuideQuick Start Guide 14Figure 2–2. Router Configuration MenuType C to select Configure Port IP Address. 3. The IAD displays the

Strona 252 - Ethernet Statistics Report

NetEngine IAD User GuideQuick Start Guide 156. The IAD displays the following information: Type the new subnet mask (usually 255.255.255.0) and press

Strona 253

NetEngine IAD User GuideQuick Start Guide 16Connecting via TelnetTo manage the IAD via the LAN (or Intranet), you must set an IP address for the Ether

Strona 254 - G7070 ADSL Statistics Report

NetEngine IAD User GuideQuick Start Guide 174.Type your password and press Enter to display the Main menu.Using the Menu InterfaceThe NetEngine IAD pr

Strona 255 - POTS Statistics Report

NetEngine IAD User GuideQuick Start Guide 18Figure 2–4. Main Menu for Supervisor Figure 2–5. Main Menu for Network Administrator Figure 2–6. Main M

Strona 256 - Clearing Media Statistics

NetEngine IAD User GuideQuick Start Guide 19Navigating the IAD Menu InterfaceMenus in the IAD configuration system are arranged hierarchically. That i

Strona 257

NetEngine IAD User GuideQuick Start Guide 20Exiting the Menu InterfaceTo exit the menu interface, return to the Main menu using the Escape key, and pr

Strona 258

. - iv - NetEngine IAD User GuideUsing the Menu Interface ...17Basic IAD Configuration ...

Strona 259

NetEngine IAD User GuideQuick Start Guide 21Making G.SHDSL ConnectionsG.SHDSL-equipped IADs use an RJ11 connector on the rear panel for WAN connection

Strona 260 - Zero All

NetEngine IAD User GuideQuick Start Guide 22Making RJ21X Connections (7000 family)The pin assignments for the RJ21X connector are telco standard. Conn

Strona 261 - IAD Reports 242

Polycom, Inc. NetEngine IAD User Guide This chapter describes how to control security to your IAD, validate users using a RADIUS server, configure SNM

Strona 262 - 13. Command Line

NetEngine IAD User GuideAdministration 24IAD SecurityTo maintain IAD security, the IAD provides multi-level login access using a single user ID and pa

Strona 263 - Command Line Interface 244

NetEngine IAD User GuideAdministration 25Table 3–2 lists the default values for the user IDs and passwords:The user ID and password may contain up to

Strona 264 - Command Line Interface 245

NetEngine IAD User GuideAdministration 26Changing the User Level User IDTo change the user ID for the User security level (the only security level tha

Strona 265 - Command Line Interface 246

NetEngine IAD User GuideAdministration 27RADIUS Server SettingsYou can use a RADIUS server to determine the validity of unknown user ID/password pairs

Strona 266 - Command Line Interface 247

NetEngine IAD User GuideAdministration 283. Type the new encryption key and press Enter.4. Reset the IAD (page 15).Displaying the RADIUS Configuration

Strona 267 - Command Line Interface 248

NetEngine IAD User GuideAdministration 29Setting Up SNMPYou can enable SNMP over IP and/or EOC (when the voice gateway is AAL2/LES CAS or ELCP). By de

Strona 268 - Command Line Interface 249

NetEngine IAD User GuideAdministration 30Enabling and Disabling SNMP via IPType E to enable or disable SNMP via IP:1. The IAD displays the current sta

Strona 269 - Command Line Interface 250

. - v - NetEngine IAD User GuideSelecting the Physical Interface ...60Configuring the G.SHDSL Interface...

Strona 270 - Command Line Interface 251

NetEngine IAD User GuideAdministration 31Configuring the System NameType N to configure the system name (up to 39 alphanumeric characters):1. The IAD

Strona 271 - Command Line Interface 252

NetEngine IAD User GuideAdministration 32Enabling or Disabling SNMP Traps via EOCType U to enable or disable SNMP traps via EOC:1. The IAD displays th

Strona 272 - Command Line Interface 253

NetEngine IAD User GuideAdministration 33Upgrading the SystemPeriodically, Verilink may provide new software that you will download to the IAD to upgr

Strona 273 - Command Line Interface 254

NetEngine IAD User GuideAdministration 342. Type X to display the File Transfer menu.Figure 3–4. File Transfer Menu 3. Type X to update the entire sy

Strona 274 - Command Line Interface 255

NetEngine IAD User GuideAdministration 35Setting up Your LAN ConnectionThe IAD LAN port may be set for full duplex Ethernet operation if your IAD is s

Strona 275 - Command Line Interface 256

NetEngine IAD User GuideAdministration 36Using System UtilitiesThe Utilities menu contains utility commands, and several menus to upgrade ACOS softwar

Strona 276 - Command Line Interface 257

NetEngine IAD User GuideAdministration 37Using Trace RouteUse Trace Route to trace the network route to a specified host. To run Trace Route, follow t

Strona 277 - Command Line Interface 258

NetEngine IAD User GuideAdministration 38Configuring the Console Timeout PeriodTo maintain security, you can set the amount of time a console or Telne

Strona 278 - Diagnostics

NetEngine IAD User GuideAdministration 392. The IAD displays the following menu:Type 1 to set the config.st config file as the boot file—or—Type 2 to

Strona 279

NetEngine IAD User GuideAdministration 401. Type A on the Utilities menu. The IAD deletes any existing reset reason, and displays the Utility menu.

Strona 280 - Performing a Hotline Test

. - vi - NetEngine IAD User GuideConfiguring DNS Client ... 114Configuring DHCP Client...

Strona 281 - Performing a Ring Test

NetEngine IAD User GuideAdministration 41Using the File SystemThe File System menu contains commands to manage files on the IAD. To display the File S

Strona 282

NetEngine IAD User GuideAdministration 42Copying FilesTo duplicate a file with a new name, follow these steps:1. Type C on the File System menu. The I

Strona 283

NetEngine IAD User GuideAdministration 43Using the Debug MenuThe Debug menu contains commands to set various debugging options. Debugging should only

Strona 284

NetEngine IAD User GuideAdministration 44Enabling and Disabling STP Debug ModeWhen you enable STP debugging, the IAD displays STP debug messages. To e

Strona 285

NetEngine IAD User GuideAdministration 45Performing File TransfersThe File Transfer menu allows you to transfer groups of files to or from the IAD. To

Strona 286 - Trouble

NetEngine IAD User GuideAdministration 46Updating ACOSType O on the File Transfer menu to display the File Transfer Method menu and download Verilink’

Strona 287

NetEngine IAD User GuideAdministration 47Type the name of the file and press Enter. To exit without transferring the file, press Escape or Enter witho

Strona 288

NetEngine IAD User GuideAdministration 48Setting Derived Timing OptionsUse the Derived Timing options to enable and disable Derived Timing, and to deb

Strona 289

NetEngine IAD User GuideAdministration 492. Type 1, 2, or 3 to enable or disable specific derived timing debugging messages.For each option, the IAD d

Strona 290 - 15. Verification

NetEngine IAD User GuideAdministration 50

Strona 291 - Operational

. - vii - NetEngine IAD User GuideSetting Jitter Delay ...142Displaying Jitter Delay...

Strona 292 - Verification 273

. NetEngine IAD User Guide This chapter describes how to configure the IAD WAN interface and datalink protocol for data operation.Basic WAN setup task

Strona 293 - Verification 274

NetEngine IAD User GuideWAN Configuration 52Basic WAN Setup TasksTo set up the IAD for voice and data operation, you must perform at least these basic

Strona 294 - A. Menu Map

NetEngine IAD User GuideWAN Configuration 53Figure 4–2. T1/E1 WAN Configuration Flowchart T1/E1InterfaceSet datalinkprotocolYe sEndConfigureATM optio

Strona 295 - Menu Map 276

NetEngine IAD User GuideWAN Configuration 54Identifying your WAN Interface and Datalink ProtocolThe sections you’ll use to perform WAN configuration d

Strona 296 - B. Country Codes

NetEngine IAD User GuideWAN Configuration 55LAN LINK LAN ACT WAN LINK VOICEPOWER66204c6208c7216cChannelized T1 with Frame Relay1. Set the datalink pro

Strona 297 - Country Codes 278

NetEngine IAD User GuideWAN Configuration 56Using the WAN Config-uration MenuConfiguring the IAD for data involves several tasks. Tasks in this chapte

Strona 298 - Specifications

NetEngine IAD User GuideWAN Configuration 57Selecting ATM or Frame RelayWhen you select ATM as the datalink protocol, the IAD displays the ATM and PVC

Strona 299 - Feature IAD Description

NetEngine IAD User GuideWAN Configuration 58Setting Up TDM VoiceTDM Voice allows you to set up data and voice circuits on channelized T1 circuits. You

Strona 300

NetEngine IAD User GuideWAN Configuration 599. The IAD asks you for the starting channel:Enter starting channel of this voice channel chunk:Type the s

Strona 301

NetEngine IAD User GuideWAN Configuration 60Selecting the Physical InterfaceOn all IADs except the 6500 series, the WAN interface is fixed. On 6500 IA

Strona 302

. - viii - NetEngine IAD User GuideDisplaying DHCP Server Assigned and Unassigned Addresses ...178Disp

Strona 303 - Features

NetEngine IAD User GuideWAN Configuration 61Configur-ing the G.SHDSL InterfaceThe tasks described in this section all begin on the G2237 xDSL Configur

Strona 304

NetEngine IAD User GuideWAN Configuration 62Selecting CPE or CO Mode1. Type 2 to display the Configure CPE/CO Mode menu.Figure 4–11. Configure CPE/CO

Strona 305 - Interface IAD Description

NetEngine IAD User GuideWAN Configuration 63Configur-ing the SDSL Interface—6500The tasks described in this section all begin on the G2237 xDSL Config

Strona 306

NetEngine IAD User GuideWAN Configuration 64Configuring the Adaptive Rate Mode1. Type 3 to display the SDSL Rate Mode menu.Figure 4–15. Configure SDS

Strona 307

NetEngine IAD User GuideWAN Configuration 65Configur-ing the SDSL InterfaceThe tasks described in this section all begin on the SDSL Configuration men

Strona 308 - D. Connector Pinouts

NetEngine IAD User GuideWAN Configuration 66Setting Auto Cycle—Nokia DSLAMType 2 to set the SDSL speed to Auto Cycle for connecting to a Nokia DSLAM.T

Strona 309 - Connector Pinouts 290

NetEngine IAD User GuideWAN Configuration 67Setting SDSL Speed for IMAS DSLAM—Nortel DSLAM1. Type 7 to set the SDSL first try speed for connecting to

Strona 310 - Signal RS-530 V.35 RS-449

NetEngine IAD User GuideWAN Configuration 682. The IAD prompts for an entry:Enter SDSL Auto Cycle Speed Entry to Configure (1..14):Type the value of t

Strona 311 - Connector Pinouts 292

NetEngine IAD User GuideWAN Configuration 69Configur-ing the ADSL InterfaceThe tasks described in this section all begin on the ADSL Configuration men

Strona 312 - E. Glossary

NetEngine IAD User GuideWAN Configuration 70Setting the Interface to T1 or E1To determine the WAN interface setting, or to switch the WAN interface fo

Strona 313 - Glossary 294

. - ix - NetEngine IAD User GuideDeleting a NAT Local Server Entry...200Deleting a NAT Alias Entry ...

Strona 314 - Glossary 295

NetEngine IAD User GuideWAN Configuration 71Switching from T1 to E1If your IAD is set for T1 and it is being deployed in an E1 environment: 1. Type 9

Strona 315 - Glossary 296

NetEngine IAD User GuideWAN Configuration 72Configur-ing the T1 InterfaceThe tasks described in this section all begin on the T1 Configuration menu. T

Strona 316

NetEngine IAD User GuideWAN Configuration 73Setting Line Build Out1. Type 2 (Select Transmit Line Build Out) to display the Line Build Out menu.Figure

Strona 317

NetEngine IAD User GuideWAN Configuration 74Figure 4–27. Loopback Menu Type the option number: 1, 2 or 3 to enable or disable Outward Payload, Outwar

Strona 318

NetEngine IAD User GuideWAN Configuration 75Enabling or Disabling Specific Channels1. Type 3 to enable or disable specific channels. If all channels a

Strona 319

NetEngine IAD User GuideWAN Configuration 76Displaying Physical Layer Stats and Alarm LogThe physical layer statistics displays the T1 error rate in e

Strona 320

NetEngine IAD User GuideWAN Configuration 77Figure 4–31. E1 Configuration menu Type the option to set the frame mode. 2. The IAD saves the configurat

Strona 321

NetEngine IAD User GuideWAN Configuration 78Figure 4–33. Configure S-Bits Menu 3. To toggle a given bit, type the corresponding option number.4. The

Strona 322

NetEngine IAD User GuideWAN Configuration 79Enabling or Disabling Specific Channels1. Type 3 to enable or disable specific channels. If all channels a

Strona 323

NetEngine IAD User GuideWAN Configuration 80Displaying Physical Layer Stats and Alarm Log1. Type P to display the physical layer statistics and the al

Komentarze do niniejszej Instrukcji

Brak uwag