Strona 1 - Installation and Operation

SpectraLink 6100 MCU Installation and Operation SpectraLink 6000 System January 2008 Edition 1725-36097-001 Version G 1

Strona 2 - Contact Information

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System PN: 1725-36097-001_G.doc 10 Installation Steps and Responsibilities 9 Task

Strona 3 - About this Guide

2 SpectraLink 6000 System Overview Review this section if you are unfamiliar with the features and operation of the SpectraLink 6000 System. System Op

Strona 4 - Icons and Conventions

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Master Control Unit (MCU) Serves as the connecting point, or gateway, betwee

Strona 5 - Contents

SpectraLink 6000 System Overview and, just like wired telephones, can receive calls directly, receive transferred calls, transfer calls to other exte

Strona 6

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System The Front Panel of the SpectraLink 6100 MCU The MCU’s front panel contains t

Strona 7

3Site Preparation Required Materials Provided by Customer The following equipment must be provided by the customer:  Outlet Strip Recommended for

Strona 8

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Determine Location of MCU Each MCU is approximately 2.75” wide, 12.5” high,

Strona 9 - Installation Overview

4Run Cable for System Run Cables to Base Station Locations The Base Station locations should be designated on the building floor plans provided to th

Strona 10 - PN: 1725-36097-001_G.doc

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Determine the amount of wire needed to connect the Base Station to the MCU b

Strona 11 - Overview

Run Cable for System Terminate Cable at Base Station Locations After running the wire to the Base Station location, terminate the wire using an RJ-4

Strona 12 - Base Stations

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Trademark Information Polycom® and the logo designs SpectraLink® LinkPlus L

Strona 13 - SpectraLink 6100 OAI Gateway

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Prepare Demarc Blocks The MCU connects to the existing telephone system usin

Strona 14

Run Cable for System Dedicated line for diagnostic modem The SpectraLink 6100 MCU can be accessed remotely using an internal modem. To use the modem

Strona 15 - Site Preparation

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Four-wire digital interface The wiring diagram below shows the connections r

Strona 16 - Determine Location of MCU

Run Cable for System Install Demarc Blocks The demarcation blocks used to connect the telephone system and Base Stations to the MCU should be install

Strona 17 - Run Cable for System

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Connect Cables from Base Stations and Phone Lines to Demarc Blocks Two-pair

Strona 18 - Pull Cable

Run Cable for System Two-wire analog or digital demarc block The demarc block for the two-wire analog or digital interface should be wired as follows

Strona 19

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Four-wire digital demarc block The four-wire digital interface (future relea

Strona 20 - Prepare Demarc Blocks

Run Cable for System Line 1 RX tipringLine 2 RX tipringLine 3 RX tipringLine 4 RX tipringLine 5 RXtipringLine 6 RX tipringLine 7 RX tipringLine

Strona 21

5Install SpectraLink 6000 System Survey Site Check the site to be sure pre-installation work has been completed correctly. This includes:  Location

Strona 22 - Four-wire digital interface

Install SpectraLink 6000 System Check Components The following items should be at the installation site.  SpectraLink 6100 Master Control Unit Dep

Strona 23 - Assign and Program Ports

About this Guide This document explains installation and operation of Polycom’s SpectraLink 6000 System, using the Link 150 Model 3 (M3) Master Contr

Strona 24 - Lines to Demarc Blocks

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Install MCUs Mount MCUs to wall The MCUs are designed to be mounted on a bac

Strona 25 - Two-wire Connector

Install SpectraLink 6000 System Connect multi-unit systems Use the following procedure to connect multiple MCUs. 1. Mount the MCUs side by side. 2.

Strona 26 - Four-wire Connector A

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Connect power 1. Connect the power plug from the AC adapter to the jack lab

Strona 27 - Four-wire Connector B

Install SpectraLink 6000 System Switch Interface Line LEDs MCU Type Notes Analog 1 SCA5xx The SCA will only support Analog. Comdial 3 SCU5xx D

Strona 28 - Survey Site

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Install Base Stations Be sure the Base Station is positioned clear of anythi

Strona 29 - Check Components

Install SpectraLink 6000 System 5. Once the Base Station is anchored to the fastener, lift the acoustical tile and plug the RJ-45 8-pin modular plug

Strona 30 - Install MCUs

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Install Outdoor Base Stations Outdoor Base Stations are equipped with a prot

Strona 31 - Connect multi-unit systems

6Connect and Register Handsets Set Up Diagnostic Modem Each MCU has an internal modem feature that allows Polycom technicians to dial into the system

Strona 32 - Set switch interface type

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Register Handsets Before a handset can be used it must be registered to a li

Strona 33

Connect and Register Handsets — Initially Line 2 will flash. This is because Line 1 is usually set up as the remote access diagnostic modem. To regis

Strona 34 - Install Base Stations

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System LinkPlus Interface Guide (1725-361xx-001 where xx indicates a number corresp

Strona 35

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System PN: 1725-36097-001_G.doc 40 Program Handset Features PBX and Key Systems pro

Strona 36

7Site Certification The Polycom field service engineer should not leave the site before contacting Polycom to perform remote install verification. Co

Strona 38 - Register Handsets

8System Administration Troubleshoot Error Codes When an alarm is detected, the ERROR LED will light and the MCU’s STATUS LEDs will display an alarm c

Strona 39 - Unregister Handsets

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Certain four-wire telephones (such as MERLIN LEGEND) use a different connec

Strona 40 - Test Handsets

System Administration The following STATUS LEDs are displayed in combination with the ERROR LED. STATUS LEDs Description Action 1, 2, 3, 4, 5 MCU ha

Strona 41 - Site Certification

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System STATUS LEDs Description Action 1, 4 The operator is trying to register a h

Strona 42

System Administration Handset Status Indicator Messages Indicator Description Action BATT Displays when user is on the handset and the battery charg

Strona 43 - System Administration

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Replace a Handset If a handset breaks or needs to be replaced, the old hands

Strona 44 - Status LED Codes

System Administration Replace an MCU When the system has more than one MCU, each MCU contains a complete set of configuration information for the enti

Strona 45

Contents 0 About this Guide ...3 Polycom Model Numbers...

Strona 46

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System PN: 1725-36097-001_G.doc 50 6. If the replacement MCU has STATUS LED 3 and

Strona 47

9Handset Planning Worksheet Copy and complete this worksheet to keep track of the port numbers, extensions, users, and features assigned to your hand

Strona 49 - Replace an MCU

PN: 1725-36097-001_G.doc 53Base Station Location Worksheet MCU: ________ Base Station # Location (e.g.: building, floor #, detailed description) Por

Strona 51 - Handset Planning Worksheet

11Technical Parameters Select Alternate Spread Spectrum Sequence The SpectraLink 6000 System uses spread spectrum radio transmission. Spread spectrum

Strona 52

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System 2. Power the system on. STATUS LEDs 5 and 1 should be lit, indicating frequ

Strona 53 - MCU: ________

Safety Notices WARNING: Changes or modifications to this equipment not approved by Polycom may cause this equipment to not comply with part 15 of t

Strona 55 - Technical Parameters

Index A AC Adapter ...29 A-law ...

Strona 56 - Change Companding

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System Demarc Blocks ...

Strona 57 - Safety Notices

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System PN: 1725-36097-001_G.doc 60 Base Station cabling...

Strona 58

Contents PN: 1725-36097-001_G.doc 79 Handset Planning Worksheet ...51 10 Base Station Location Works

Strona 60

1 Installation Overview Installation has three phases. In most cases, a separate person is responsible for each phase. 1. Site preparation and wire i